Position the outlet and rack ready for connection to the cables. The rack can be reversed and screwed on the front of the console ready for termination. |
![]() |
![]() |
Strip the sheath from the cables exposing the twisted pairs ready for termination. Check continuity and attach final identification labels on each end of the cables for future reference. |
![]() |
![]() |
Carefully terminate the cables using the impact insertion tool. It is very important that each pair are not untwisted more than 13mm from the termination connections. |
![]() |
|
|
Secure the cables using the grip ties supplied do not overtighten and crush the cables. You can now secure the faceplate and rack ensuring cables are not trapped.. |
![]() |
|
|
To test the installation connections insert a patch cord into outlet No.1 and tester port 568 A\B. Insert the other patch cord into rack No.1 and tester port 568 A\B. Both testers should show a sequence of 4 green lights flashing from 4-5 through to 7-8. Any other sequence or red lights determines the cables are incorrect and be checked and re-tested. This test should be carried out on all numbered circuits. |
![]() |
|
Wiring Diagram For A RJ45 Outlet
|
Wiring Diagram For A 24 Way Rack
1 = White / Orange ------- 2 = Orange / White PLEASE NOTE THE FOLLOWING CAUSES OF FAILED CABLES Over tightened crimp ties on cables. |